References

Brick, Block & Mortar

323 sources in the library on brick, block & mortar. Each one says what the document covers and what it is good for. Name a source to see which document it is and where to read it. One at a time. Page 6 of 9.

  1. supplier figure RN-MA7VQU

    H+H UK

    Celcon Plus Blocks, the large format thin-joint range. Available at compressive strengths 2.9, 3.6, 7.3 and 8.7 N/mm2 with matching thermal conductivities 0.11, 0.15 and 0.18 W/mK, from a density of 400 kg/m3. Laid with Celfix thin layer mortar rather than a conventional 10 mm bed.

  2. supplier figure RN-9RFNFX

    Helifix (Leviat)

    BowTie is a long stainless steel tie that stabilises bulging walls by securing them into the ends of internal floor joists, with no external pattress plates. The BowTie HD is a heavy duty 12 mm diameter threaded bar with a self-cutting end, used where the wall must be tied back to internal floor joists or roof beams running parallel to it. Self-tapping so timbers do not split, suitable for hardwood, and installed from outside. Kit components: clearance-hole drill bit, BowTies, power support tool, HD Driver, hand support tool, and PolyPlus resin cartridge with extension nozzles and applicator.

  3. supplier figure RN-VQLRYT

    Helifix (Leviat)

    Kit contents: 10 x 1 m lengths of 6 mm HeliBar, one 3 litre tub of HeliBond cementitious grout, mortar chisel and rake, mixing paddle, and an applicator with nozzle. A 3-jaw-chuck power drill is needed but not supplied. Dimensions that matter: slots are cut into the horizontal mortar beds a minimum of 500 mm either side of the crack, and are 10 mm wide as standard to take the 6 mm HeliBar, with 4.5 mm HeliBar used for thin joints. Where two or more cracks are close together one continuous bar is used, long enough to extend 500 mm beyond the outer cracks, so three cracks at 250 mm apart need a 1.5 m bar. Slots are prepared with HeliPrimer WB or thoroughly wetted, HeliBond is the recommended bonding agent, and PolyPlus resin is used for small jobs or where load is applied quickly. Suitable for listed and historic structures and lime mortar.

  4. supplier figure RN-AW2DTD

    Helifix (Leviat)

    HeliBar is austenitic stainless steel helical reinforcing bar. It starts as round wire with a typical 0.2% proof stress of 500 N/mm2; the cold forming process that creates the helical hi-fin profile more than doubles that to around 1100 N/mm2. Bars are bonded into cut slots with HeliBond thixotropic cementitious grout, the composite action being the basis of the Helibeam System. Short 1 m lengths are used singly for crack stitching; longer lengths are used in pairs to form masonry beams that redistribute loads from foundation movement, and to create or reinstate failed lintels. Using 400 mm bars bonded at one end only, with the free end in a bonded sleeve, forms a movement joint. Applications listed include crack stitching, lintel repair, deep masonry beams, horizontal restraint with BowTie, reconnecting separated walls, securing parapets and supporting masonry over new openings.

  5. supplier figure RN-GXC3WT

    Ibstock

    Ibstock code A0270A, Aldridge Multi Rustic, wirecut extruded with a rusticated face, made at Aldridge. Dimensions 215 x 102 x 65 mm, size tolerance T2 R1, vertically perforated with 27-32% voids. Compressive strength 25 N/mm2, active soluble salts S2, water absorption 12% by weight, durability F2. Gross dry density 1470 kg/m3, equivalent thermal conductivity K value at 5% exposed 1.09 W/mK, initial rate of absorption (suction rate) 0.7 kg/m2/min. Dry brick weight 2 kg, pack quantity 500.

  6. supplier figure RN-NGY0UA

    Ibstock

    Ibstock code A4057A, Ashdown Medium Multi. Dimensions 215 x 102 x 65 mm, size tolerance T1 R1, single frog with 10-15% voids. Compressive strength 30 N/mm2, active soluble salts S2, water absorption 15% by weight, durability F2. Gross dry density 1610 kg/m3, equivalent thermal conductivity K value at 5% exposed 0.86 W/mK, initial rate of absorption 1.9 kg/m2/min, which is high enough that the brick will need wetting or a water-retentive mortar in warm weather.

  7. supplier figure RN-MMH1NP

    Ibstock

    Ibstock code A0129A, Aston Burnt Red. Dimensions 215 x 102 x 65 mm, tolerance T2 R1, vertically perforated with 33-38% voids, the highest void ratio of the Ibstock bricks listed here. Compressive strength 25 N/mm2, active soluble salts S2, water absorption 12%, durability F2. Gross dry density 1600 kg/m3, equivalent thermal conductivity K value at 5% exposed 1.16 W/mK, initial rate of absorption 0.3 kg/m2/min.

  8. supplier figure RN-DI0GDB

    Ibstock

    Ibstock code A2601A, Beamish Blend. Dimensions 215 x 102 x 65 mm, tolerance Tm Rm, solid with 0% voids. Compressive strength 20 N/mm2, active soluble salts S2, water absorption 12% by weight, durability F2. Gross dry density 1740 kg/m3, equivalent thermal conductivity K value at 5% exposed 0.86 W/mK, initial rate of absorption 0.6 kg/m2/min. A solid, no-void brick, which matters where the brick is cut or exposed on edge.

  9. supplier figure RN-CZED6F

    IG Lintels (Keystone Group)

    HDBOX 100, SKU HDBOX/K100, heavy duty closed box lintel used to support openings in 100 mm wide internal walls, wall depth 100-140 mm. Total UDL by length: 600-1200 mm, 150 mm high, 2.5 mm steel, 50 kN; 1350-1800 mm, 150 mm high, 2.5 mm, 45 kN; 1950-2400 mm, 215 mm high, 2.5 mm, 50 kN; 2550-2700 mm, 215 mm high, 2.5 mm, 40 kN. Sister sizes HDBOX 140 and HDBOX 200 cover wider walls.

  10. supplier figure RN-TDGR73

    IG Lintels (Keystone Group)

    HDBOX 140, SKU HDBOX/K150, heavy duty closed box lintel used to support openings in 150 mm wide walls, wall depth 100-140 mm. Total UDL by length: 600-1200 mm, 150 mm high, 2.5 mm steel, 50 kN; 1350-1800 mm, 150 mm high, 45 kN; 1950-2400 mm, 215 mm high, 50 kN; 2550-2700 mm, 215 mm high, 40 kN.

  11. supplier figure RN-3CE9B0

    IG Lintels (Keystone Group)

    HT/HD+ 100 Hi-therm heavy duty thermally broken lintel for 90-105 mm cavities. Total UDL at 3:1 and 19:1 load ratios by length band: 600-1500 mm, 144 mm high, 2.9 mm steel, 30 kN and 22 kN; 1650-2400 mm, 226 mm high, 2.9 mm, 35 kN and 35 kN; 2550-3000 mm, 226 mm high, 3.2 mm, 35 kN and 35 kN; 3150-3600 mm, 215 mm high, 2.9 mm, 35 kN and 32 kN.

  12. supplier figure RN-ZB4A3Z

    IG Lintels (Keystone Group)

    INT 100, SKU INT/K-100, light internal lintel for solid walls. Overall length 900 mm gives a 700 mm maximum span at 7 kN total UDL; 1050 mm gives 850 mm at 7 kN; 1100 mm gives 900 mm at 7 kN; 1200 mm gives 1000 mm at 7 kN. IG state that one course of mortar must be allowed to cure for at least 24 hours before additional loads are applied, and that INT 100 is not suitable for floor loads. Specify INT 64 for a 75 mm solid wall.

  13. supplier figure RN-KFYJSE

    IG Lintels (Keystone Group)

    L1/HD 100 heavy duty lintel for 90-105 mm cavities, 102 mm outer leaf, 100 mm inner leaf. Total UDL by length band, quoted at 3:1 and 19:1 inner-to-outer load ratios: 600-1200 mm, 109 mm high, 2.9 mm steel, 30 kN and 22 kN; 1350-1500 mm, 136 mm high, 2.9 mm, 30 kN and 22 kN; 1650-2100 mm, 161 mm high, 2.9 mm, 40 kN and 35 kN; 2250-2550 mm, 199 mm high, 2.9 mm, 40 kN and 35 kN; 2700-3000 mm, 199 mm high, 3.2 mm, 40 kN and 35 kN.

  14. supplier figure RN-UQH4M2

    IG Lintels (Keystone Group)

    L1/S 100 standard load lintel for 90-105 mm cavities, 102 mm outer leaf, 100 mm inner leaf. Loading table by manufactured length: 600-1200 mm, 87 mm high, 1.6 mm steel, total UDL 12 kN at a 3:1 load ratio and 10 kN at 19:1; 1350-1500 mm, 87 mm high, 1.8 mm steel, 16 kN and 13 kN; 1650-1800 mm, 107 mm high, and so on up the range. Lengths are made in 150 mm increments.

  15. supplier figure RN-R96EYL

    IG Lintels (Keystone Group)

    L1/S 50, SKU SK50, standard load lintel for the narrow 50-65 mm cavities common in older housing, 102 mm outer leaf, 100 mm inner leaf. Loading table by manufactured length: 600-1200 mm, 79 mm high, 1.6 mm steel, total UDL 12 kN at a 3:1 load ratio and 10 kN at 19:1; 1350-1500 mm, 96 mm high, 1.8 mm steel, 14 kN and 12 kN; the range continues from 1650-1800 mm upward. Made in 150 mm length increments.

  16. supplier figure RN-IMDK0U

    IG Lintels (Keystone Group)

    L1/XHD 100 extra heavy duty lintel for 90-105 mm cavities, 102 mm outer leaf, 100 mm inner leaf. Total UDL at 3:1 and 19:1: 600-1500 mm, 162 mm high, 3.2 mm steel, 50 kN and 45 kN; 1650-1800 mm, 162 mm high, 3.2 mm, 50 kN and 45 kN; 1950-2100 mm, 199 mm high, 3.2 mm, 55 kN and 45 kN; 2250-2700 mm, 199 mm high, 3.2 mm, 50 kN. Made in 150 mm length increments.

  17. supplier figure RN-IOTSIQ

    IG Lintels (Keystone Group)

    L9 solid wall lintel, SKU SW/K. Total UDL by length band: 600-1200 mm, 58 mm high, 2.5 mm steel, 6 kN; 1350-1650 mm, 93 mm high, 2.5 mm, 8 kN; 1800-2100 mm, 94 mm high, 2.9 mm, 8 kN; 2250-2700 mm, 117 mm high, 3.0 mm, 10 kN. IG state the lintel must be built in as shown to achieve the loading figures, and that lintels may be propped to speed construction.

  18. supplier figure RN-U0I7NA

    IG Lintels (Keystone Group)

    The full IG load-table book, CI/SfB Hh2 (31.9). Lintels are designed to BS 5977 Part 2 1983 and BS EN 845-2:2003, tabulated at both a 3:1 and a 19:1 inner-to-outer load ratio. L1/S 100 for 90-105 mm cavities: height 88 mm and 1.6 mm steel at 600-1200 mm giving 12 kN at 3:1 and 10 kN at 19:1, rising through 107 mm/19 kN, 125 mm/21 kN, 150 mm/23 kN, 162 mm/27 kN to 200 mm high 3.4 mm steel at 4200-4800 mm giving 27 kN and 22 kN. L1/S 110, 130 and 150 for 110-125, 130-145 and 150-165 mm cavities all run 16/22/24/27/26/25 kN at 3:1. L1/HD 100 gives 30 kN to 1500 mm and 40 kN from 1650 to 3000 mm. INT 100 solid wall lintel: 900 mm overall for a 700 mm maximum span at 7 kN, up to 1200 mm overall for a 1000 mm span at 7 kN, not suitable for floor loads. L9/SW 100 for 100-150 mm solid walls gives 6 to 10 kN. The insulation is expanded polystyrene at 0.03 W/mK, CFC and formaldehyde free. A damp proof course is required over all lintels.

  19. supplier figure RN-A9044P

    IKO PLC

    IKO Hyload Original damp proof course: 1.25mm thick, supplied in 20m (20,000mm) rolls in widths of 100, 112.5, 150, 175, 225, 275, 300, 337.5, 350, 360, 375, 400, 450, 500, 525, 600, 650, 700, 750, 800, 900 and 1000mm. BBA certified since 1967 and CE marked.

  20. supplier figure RN-5A7R2N

    James Hardie

    Fibre cement tile backer board in 6 mm and 12 mm thicknesses, both 1200 x 800 mm. Weight 9 kg for the 6 mm board and 13.8 kg for the 12 mm board. Reaction to Fire A1 for both. Stated hanging weight capacity 200 kg/m2, for residential projects on timber studs only; commercial projects using metal stud profiles require engineer input. Cut by score and snap or standard power tools and screwed to timber, metal or masonry substructures.

  21. supplier figure RN-4AK512

    James Hardie

    Large format fibre cement facade board in 8 mm and 11 mm thicknesses. Sheet sizes raw 2438 mm (net 2428 mm) and raw 3048 mm (net 3038 mm) long by raw 1220 mm (net 1210 mm) wide. Weight 10.2 kg/m2 at 8 mm and 14.4 kg/m2 at 11 mm. Fire Classification A2-s1, d0 for both thicknesses. Natural fibre cement texture, 6 standard colours with custom colour on request.

  22. supplier figure RN-XR6MCG

    James Hardie

    Fibre cement plank with a cedar texture. Thickness 11 mm, length 3600 mm, width 214 mm with a 182 mm visible surface. Weight 10.5 kg per piece; 1.52 pieces per m2. Fire Classification A2-s1, d0. Eight standard colours.

  23. supplier figure RN-4WZ6B3

    K Rend (Kilwaughter Minerals)

    Cement based polymer modified basecoat, 25 kg sacks, mixed with 5 to 6 litres of clean water and at least 5 minutes mixing. Coverage 1.8 kg per mm thickness per m2, requiring approximately 8 to 11 kg/m2 at a nominal 4 to 6 mm thickness. Kitemark classifications: compressive strength CS IV, capillary water absorption category W2, thermal conductivity P=50% 0.46. Also used as an insulation bedding adhesive for polystyrene boards onto masonry, applied as a continuous perimeter line plus centre dabs covering at least 50% of the board, or with a notched trowel over the whole board face. Alkali resistant reinforcing mesh may be required.

  24. supplier figure RN-A5WNP7

    K Rend (Kilwaughter Minerals)

    Modified acrylic bonding coat used to improve adhesion of K Rend renders to difficult substrates. Density approximately 1.2 kg/m3 as stated on the sheet. Coverage approximately 0.25 to 0.45 kg/m2 depending on substrate. Tools and equipment cleaned with water immediately after use.

  25. supplier figure RN-RPDNZT

    K Rend (Kilwaughter Minerals)

    Ready to use organic resin thin coat render with silicone resin emulsion and acrylic dispersion, supplied in 25 kg buckets. Coverage by grain size: TC 05 (largest grain 0.5 mm) about 16 m2 per 25 kg bucket or 1.6 kg/m2 by hand and about 20 m2 or 1.3 kg/m2 sprayed; TC 10 (1.0 mm) about 14 m2 or 1.8 kg/m2; TC 15 (1.5 mm) about 10 m2 or 2.5 kg/m2; TC 30 (3.0 mm) about 5 m2 or 5 kg/m2. Classified to BS EN 15824: 2009: water vapour permeability Category V2, water absorption Category W3, adhesion 0.65 MPa, thermal conductivity lambda10 dry 0.83 (P=50%) and 0.93 (P=90%), density approximately 1,800 kg/m3, designation Coating Material DIN 18558 P Org 1. Reaction to fire Class A2-s1,d0. Substrate and air minimum 5 C at application; allow freshly applied basecoats a minimum of 14 days; prime with K Rend Primer TC and allow 24 hours.

  26. supplier figure RN-DCOEEL

    Keystone Lintels

    HT/S+ standard load Hi-therm+ lintel tables. HT/S+ 100 for 90-105 mm cavities, made in 150 mm length increments, total UDL quoted at 3:1 and 19:1 inner-to-outer ratios: 600-1200 mm, 100 mm high, 1.6 mm steel, 12 kN and 10 kN; 1350-1500 mm, 107 mm, 2.0 mm, 16 and 13; 1650-1800 mm, 150 mm, 2.0 mm, 19 and 16; 1950-2100 mm, 150 mm, 2.0/2.5 mm, 21 and 17; 2250-2400 mm, 175 mm, 23 and 18; 2550-2700 mm, 190 mm, 2.5 mm, 27 and 22; 2850-3000 mm, 190 mm, 27 and 20; 3150-3600 mm, 234 mm, 2.9 mm, 27 and 20; 3750-4200 mm, 234 mm, 3.2 mm, 27 and 22. HT/S+ 110 and wider cavities follow on the same page.

  27. supplier figure RN-S50D2W

    Kingspan Insulation

    Rock mineral fibre slab with a thermal conductivity of 0.036 W/mK and a density of 28 to 32 kg/m3. Slab size 1.22 m x 0.61 m, so 610 mm wide slabs friction fit between studs at 600 mm centres. Fire: under System 1 AVCP, K-Roc Framing Slab achieves European Classification (Euroclass) A1 when classified to EN 13501-1: 2018. Supporting fire resistance test reports to BS EN 1364-1: 2015 and a BS EN 13501-2: 2016 classification report are listed.

  28. supplier figure RN-F3IQXN

    Kingspan Insulation

    Partial fill cavity board, phenolic core to BS EN 13166: 2012 + A2: 2016. Thermal conductivity 0.019 W/mK. Declared compressive strength 100 kPa to BS EN 826: 2013. Board size 1200 x 450 mm. BBA Certificate 16/5299 covers thicknesses 25 to 150 mm from Pembridge. Published R-values (m2K/W): 40 mm 2.10, 50 mm 2.60, 60 mm 3.15, 70 mm 3.65, 75 mm 3.90, 80 mm 4.20, 90 mm 4.70, 100 mm 5.25, 110 mm 5.75, 120 mm 6.30, 150 mm 7.85. Fire: under System 4 AVCP, K108 has a Euroclass rating of F.

  29. supplier figure RN-OOC1K5

    Kingspan Insulation

    Phenolic framing board, 2400 x 1200 mm, thermal conductivity 0.019 W/mK. Declared compressive strength 100 kPa to BS EN 826: 2013. BBA Certificate covers thicknesses 25 to 150 mm. Published R-values (m2K/W): 25 mm 1.30, 40 mm 2.10, 50 mm 2.60, 60 mm 3.15, 70 mm 3.65, 75 mm 3.90, 80 mm 4.20, 90 mm 4.70, 100 mm 5.25, 110 mm 5.75, 120 mm 6.30, 130 mm 6.80, 140 mm 7.35, 150 mm 7.85. Fire: under System 4 AVCP, K112 has a Euroclass rating of F. A tested wall build-up of 32.5 mm K118 on 89 x 38 mm studs at 600 mm centres with 50 mm K112, 9 mm OSB and nilvent membrane achieved 41 minutes integrity, insulation and loadbearing capacity under EN 13501-2: 2016 (report EUI-21-000441, 8 February 2022).

  30. supplier figure RN-O2O37D

    Kingspan Insulation

    Phenolic insulation core bonded to 12.5 mm tapered edge gypsum plasterboard, board size 2400 x 1200 mm. Insulation core thermal conductivity 0.019 W/mK; plasterboard component 0.19 W/mK. Published R-values by product thickness (m2K/W): 25 mm 1.30, 30 mm 1.55, 40 mm 2.10, 45 mm 2.35, 50 mm 2.60, 60 mm 3.15, 70 mm 3.65, 80 mm 4.20, plus 0.065 for the 12.5 mm plasterboard component. Water vapour resistance of the non-plasterboard component typically greater than 100 MNs/g to BS EN 12086: 2013; take the plasterboard component as 50 MNs/gm resistivity for condensation risk. Fire: K118 achieves European Classification (Euroclass) B-s1,d0 when classified to EN 13501-1: 2018, and the plasterboard element alone achieves Euroclass A2-s1,d0.

  31. supplier figure RN-GLCVCX

    Kingspan Insulation

    Phenolic rainscreen board, 2400 x 1200 mm, covered by BBA Certificate 14/5134 in thicknesses 25 to 150 mm. Two declared lambda values: 0.022 W/mK for insulant thickness 25 to 44 mm, and 0.021 W/mK for 45 to 150 mm. Declared compressive strength 100 kPa to BS EN 826: 2013. Published R-values (m2K/W) start at 50 mm 2.35, 60 mm 2.85, 70 mm 3.30. Fire: K15 achieves European Classification (Euroclass) C-s2,d0 when classified to EN 13501-1: 2018, test reference EUI-22-SBI-000057-A, with BS 8414 tested system reports listed separately.

  32. supplier figure RN-NALG7W

    Kingspan Insulation

    Phenolic external wall board for render and brick slip systems, 1200 x 600 mm. Two declared lambda values: 0.022 W/mK for insulant thickness 25 to 44 mm, and 0.021 W/mK for 45 to 100 mm. Declared compressive strength 100 kPa to EN 826: 2013. R-value at 25 mm is 1.10 m2K/W and rises with thickness. Fire: K5 achieves European Classification (Euroclass) C-s2,d0 when classified to EN 13501-1: 2018, test report EUI-22-SBI-000352 and classification report EUI-22-000352.

  33. supplier figure RN-Z9SPFU

    Kingspan Insulation

    Rigid thermoset polyisocyanurate partial fill cavity board faced both sides with a low emissivity composite foil, board size 1200 x 450 mm. Declared thermal conductivity 0.022 W/mK. Declared compressive stress 120 kPa at 10% compression to BS EN 826. Water vapour resistance greater than 50 MNs/g for the insulation core and greater than 100 MNs/g for the composite foil facing to BS EN 12086. BBA coverage stated for thicknesses 25 to 120 mm. Fire: under System 4 AVCP, TW50 has a Euroclass rating of F.

  34. supplier figure RN-HSPYWT

    Kingspan Insulation

    Fibre-free rigid thermoset polyisocyanurate (PIR) board for timber and steel framing to BS EN 13165: 2012 + A2: 2016, low emissivity composite foil both faces. Declared compressive stress 120 kPa at 10% compression to BS EN 826. Water vapour resistance to BS EN 12086 greater than 50 MNs/g for the insulation core and greater than 100 MNs/g for the composite foil facing (Pembridge and Selby production). Published R-values (m2K/W): 25 mm 1.10, 30 mm 1.35, 40 mm 1.80, 50 mm 2.25, 60 mm 2.70, 70 mm 3.15, 75 mm 3.40, 80 mm 3.60, 90 mm 4.05, 100 mm 4.50, 110 mm 5.00, 120 mm 5.45, 125 mm 5.65, 130 mm 5.90, 140 mm 6.35, 150 mm 6.80, which correspond to a 0.022 W/mK lambda. Fire: under System 4 AVCP, TW55 has a Euroclass rating of F.

  35. supplier figure RN-LMDZSS

    Knauf

    Manufacturer product data for 12.5mm moisture resistant plasterboard. Sheets are 1200mm wide at 2400mm (27.36 kg), 2700mm (30.78 kg) and 3000mm (34.2 kg). Comparing directly with the same maker's standard 12.5mm wallboard at 24.333 kg for a 2400mm sheet, the moisture panel is about 12 per cent heavier for identical dimensions, the additional mass being the water repellent additive in the core. There is no small format sheet in this range, so every board is a two person lift.

  36. supplier figure RN-Q17DQ9

    Knauf

    Manufacturer product data for 12.5mm high density acoustic plasterboard. Sheets are 1200mm wide at 2400mm (33.12 kg), 2700mm (37.26 kg) and 3000mm (41.4 kg), which works out at about 11.5 kg per m2. Set against the same maker's standard 12.5mm wallboard at 24.333 kg for an identical 1200 x 2400mm sheet, the acoustic board is 36 per cent heavier, and that added mass is the entire acoustic mechanism. It is also 8.8 kg heavier per sheet, which is what makes a soundproofing upgrade physically harder work than a plain reboard.

  37. supplier figure RN-65PLTP

    Knauf

    Manufacturer product data for Knauf Soundshield Plus 15mm high density acoustic plasterboard. Boards are 1200mm wide and 15mm thick, supplied at 2400mm, 2700mm and 3000mm lengths weighing 38.304 kg, 43.092 kg and 47.88 kg per board respectively. That works out at roughly 13.3 kg per m2, about a third heavier than standard 12.5mm wallboard, which is the whole point of the board and also the reason a 2.4m sheet is a two person lift. Knauf states that as part of a full Knauf system the 15mm board contributes up to 54 dB Rw sound reduction and up to 120 minutes fire protection, and carries a severe duty impact rating.

  38. supplier figure RN-SHIG71

    Knauf

    Manufacturer product data for standard 12.5mm plasterboard. Sheets are 1200mm wide at 2400mm (24.333 kg), 2500mm (23.7 kg), 2700mm (29.16 kg) and 3000mm (28.44 kg and 29.52 kg on the variants), plus a small 900 x 1800mm sheet at 12.8 kg. The 900 x 1800mm sheet at 12.8 kg is the one that matters for a domestic job because a single person can carry it up a staircase, while a 1200 x 2400mm sheet at over 24 kg needs two. The board is stated as suited to receive a plaster, a ready-mixed finish or direct decoration.

  39. supplier figure RN-AB6IQB

    Knauf

    Manufacturer product data for 9.5mm standard plasterboard, the thinner board normally used on ceilings and for overboarding. Sheets are 1200 x 1800mm at 17.856 kg and 1200 x 2400mm, with a 900mm wide sheet at 10.044 kg. Comparing with the same maker's 12.5mm wallboard at 24.333 kg for a 1200 x 2400mm sheet, the 9.5mm board is meaningfully lighter, which is why it is the ceiling board, but it also has less fire and acoustic mass and needs closer joist centres to avoid sagging.

  40. supplier figure RN-JGE6YW

    Knauf

    Manufacturer product data for standard plasterboard with an integral vapour control layer, the board used on the warm side of an insulated wall or roof to stop moisture reaching the cold structure. Sheets are 1200mm wide at 2400mm (22.75 kg), 2438mm (23.11 kg) and 2700mm (25.6 kg), plus a 900 x 1800mm sheet at 12.8 kg. It is lighter than the same maker's plain 12.5mm wallboard at 2400mm (24.333 kg), so the vapour layer adds no meaningful weight and the choice is purely about the wall build-up.