Structural insulated panels (SIPs), a North American system that has been certified in the UK since about 2000, have moved from a niche product used mainly in self-build new homes to a mainstream option for UK house extensions.1 The appeal is straightforward: a SIPs shell can be erected in a day or two for a typical single-storey extension, reaches weathertight faster than blockwork, and delivers excellent thermal performance from the outset. Whether that speed premium translates to genuine cost savings depends on your project’s specifics.

What Are SIPs?

A structural insulated panel consists of a rigid foam insulation core, typically EPS (expanded polystyrene) or PIR (polyisocyanurate), bonded under pressure between two structural facing boards, usually OSB/3 (oriented strand board). The result is a composite sandwich panel that acts as both structure and insulation simultaneously.

Standard panel thicknesses for UK residential extensions:

Panel ThicknessInsulation CoreApprox. U-value (W/m²K)Typical Use
122 mm (EPS)100 mm EPS0.31Garden rooms; below Part L for an extension wall
147 mm (EPS)125 mm EPS0.25Needs added insulation for an extension wall
172 mm (EPS)150 mm EPS0.21Needs a small insulation top-up for an extension wall
172 mm (PUR/PIR)142 mm urethane0.17Meets the extension wall limit unaided
222 mm (EPS)200 mm EPS0.16Low-energy wall

The EPS figures are one maker’s published values for panels with OSB facings: its 172 mm panel, with 150 mm of EPS, is rated at 0.21 W/m²K.2 Graphite-enhanced EPS and urethane cores do better for the same thickness. Kingspan rates its 142 mm TEK panel, a 112 mm urethane core between two 15 mm OSB/3 facings, at a worst-case whole-wall U-value of 0.20 W/m²K with no additional insulation, and its 172 mm panel at 0.17 W/m²K.3 For a new wall in an extension, Approved Document L sets a limiting U-value of 0.18 W/m²K, so most EPS panels need extra insulation, usually in the service void, to comply.4

For roof panels, thicknesses of 172–300 mm are common; roofs typically need better U-values than walls (target 0.15 W/m²K under Part L 2022).4

SIPs Extension Costs (2026)

Supply-Only Panel Cost

Panel TypeSupply Cost (per m² of panel)
122 mm EPS SIP£35–£55
147 mm EPS SIP£45–£70
172 mm EPS SIP£55–£90
172 mm PUR/PIR SIP£50–£120
Roof panels (200+ mm EPS)£65–£110

Panels are factory-cut to your specific layout, with apertures pre-cut for windows and doors. Design and cutting are often included in the quoted price above a minimum order size. Uncut stock panels cost less: one maker lists a 172 mm urethane-core panel at £150.00 inc. VAT for a 2440 × 1220 mm sheet, about £50 per m², before design, cutting, splines and fixings.5

Full Extension Cost Breakdown (25 m² single-storey rear, 2026)

ElementTypical Cost
Groundworks and foundations (concrete slab)£8,000–£14,000
SIPs panels (wall and roof, supply)£7,000–£14,000
Erection (specialist team, 1–2 days)£3,000–£6,000
Structural timber sole plate and ridge beam£1,500–£3,500
Roofing membrane, battens, tiles/slate£3,500–£7,000
External cladding or render (on SIPs OSB)£3,000–£8,000
Windows and doors£4,000–£12,000
First and second fix (electrics, plumbing)£4,000–£10,000
Internal finishes (boarding, skimming, flooring)£4,000–£10,000
Architect/technologist drawings and Regs£2,000–£5,000
Total£40,000–£89,500
Per m² finished£1,600–£3,580

The wide range reflects the difference between a budget-spec (render finish, uPVC windows, vinyl flooring) and a high-spec fit-out (brick slip cladding, aluminium bifolds, engineered timber floor).

SIPs vs Blockwork vs Timber Frame

FactorSIPsBlockwork (cavity)Light Timber Frame
Programme (weathertight)1–3 days shell erection4–10 weeks brickwork1–3 weeks
Thermal performanceExcellent out-of-boxRequires significant insulation thicknessGood with modern spec
AirtightnessExcellent if taped correctlyModerate; requires added membranesGood with membranes
Self-build suitabilityModerate, specialist tool neededHighModerate
Trades availabilitySpecialist erector neededAll builders can do itWidely understood
Design flexibilityHigh (factory-cut to spec)UnlimitedHigh
Fire performanceOSB chars; core must be protectedInherently non-combustibleRequires protection
Approximate structural cost£130–£200/m²£90–£160/m²£100–£175/m²
Typical total (finished, mid-spec)£2,200/m²£2,400/m²£2,100/m²

SIPs are not inherently cheaper to build than other methods, the panel supply cost is higher than buying bricks and blocks, but on projects with tight programmes (rental properties, limited disruption, winter builds) the speed advantage can meaningfully reduce overall cost through reduced scaffolding time, faster thermal envelope closure, and shorter contract periods.

Thermal and Airtightness Performance

SIPs extensions can readily achieve air permeability below 3 m³/h/m² at 50 Pa when the joints are sealed properly. Kingspan says its TEK system can achieve air leakage levels as good as about 1 m³/h/m² at 50 Pa.6 The critical workmanship points are:

  1. Panel-to-panel joints, must be taped internally with a VCL (vapour control layer) tape
  2. Sole plate junction, the joint where the panel meets the floor is the most common air leakage point; a continuous bead of acoustic sealant and VCL tape is standard
  3. Window and door reveals, factory-cut reveals make this easier than stud frame; still requires careful taping and air-sealing at the frame perimeter

Planning and Building Regulations

SIPs extensions are assessed identically to any other extension under planning, the system does not distinguish by material. Building Regulations requirements to note:

  • Structural calculations, required; the SIPs supplier typically provides these for their panel system; a structural engineer sign-off is expected by building control
  • Fire (Part B), SIPs using OSB facings require protection if within 1 m of a boundary; internally, OSB is typically covered by plasterboard before occupation which provides the necessary fire performance7
  • Condensation (Part C), the inner OSB facing and taped joints resist vapour on the warm side, so makers such as Kingspan say no separate vapour control layer is needed if their jointing and ventilation guidance is followed, though a condensation risk analysis to BS 5250 is still recommended3
  • Thermal (Part L), well-specified SIPs panels achieve current targets without difficulty; confirm U-values with your supplier at the design stage4

Pros and Cons Summary

Pros:

  • Very fast to weathertight
  • Excellent thermal performance from the factory
  • Reduced wet trades compared to blockwork
  • Lower on-site waste than masonry
  • Consistent quality (factory-manufactured, not site-built)

Cons:

  • Less flexible for changes once ordered; amendments to panel designs are expensive
  • Requires a specialist erection team; not all local builders are familiar with SIPs
  • Penetrations (electrics, plumbing) need careful planning, chasing is not an option in the panel faces3
  • OSB facing is moisture-sensitive during construction; panels must be protected from extended rain exposure before cladding3
  • Fewer contractors to quote means less competitive pricing in some areas

Finding SIPs Suppliers and Builders

The Structural Timber Association has counted 15 of its members operating in the SIPs market, from Kingspan’s TEK system to smaller makers.1 Most offer a full design service, structural calculations, and supply-only or supply-and-erect packages. Many also carry BBA (British Board of Agrément) certification for their panel system, which building control bodies commonly look for as evidence that the system is fit for purpose.1 UKAS suspended the BBA’s accreditation on 26 February 2026, so while that stands the BBA cannot issue new accredited certificates. A certificate issued before that date remains valid, and an equivalent from another UKAS-accredited certification body, or a European Technical Assessment, carries the same weight with building control.8

Ask for references from completed extensions (not just new builds) and check whether the price includes panel cutting, fixing hardware, and tape/sealant or whether these are extras. In the breakdown above the panels are about 16–18% of the total extension cost (£7,000 of £40,000 and £14,000 of £89,500); if a quote’s panel share is far higher, the other package elements may be underpriced and subject to overrun.

References (8)

Figures in this note were checked against the sources below on 30 September 2026. Superscript numbers in the text point to them. Every source the site cites, by topic.

  1. 1technicalgoodStructural Timber Association, guidance.RN-4XLSRLThe Structural Timber Association's SIPs guide says the SIPs market was led by North America, that certified SIPs have been available in the UK since 2000, and that SIPs are now recognised as mainstream.
  2. 2technicalsupplier figureFuture SIPs, guidance.RN-QQKEQMA UK EPS SIP maker's product table giving insulation thickness, panel thickness and U-value for each panel: 100 mm/122 mm 0.31, 125 mm/147 mm 0.25, 150 mm/172 mm 0.21, 200 mm/222 mm 0.16.
  3. 3technicalsupplier figureKingspan Insulation, guidance.RN-BYJX5TKingspan's specification manual for the TEK SIP system gives the panel build-up (112 or 142 mm urethane core between 15 mm OSB/3) and worst-case whole wall U-values of 0.20 for 142 mm and 0.17 for 172 mm panels. Maker's own manual served from its document CDN.
  4. 4technicalvery strongMinistry of Housing, Communities and Local Government.RN-L0FCJXThe in-force U-value tables a DIY insulation or door note must quote, with the exact numbers. Table 4.2, limiting U-values for new fabric elements in existing dwellings, sets roof 0.15, wall 0.18, floor 0.18, swimming pool basin 0.25, window 1.4 or Window Energy Rating Band B minimum, rooflight 2.2, doors with more than 60 per cent of the internal face glazed 1.4 or Doorset Energy Rating Band C minimum, and other doors 1.4 or Doorset Energy Rating Band B minimum. Table 4.3, for existing elements, gives a roof threshold of 0.35 and an improved value of 0.16, which is the figure a loft insulation note needs: paragraph 4.12 says a retained element whose U-value is higher than the column (a) threshold, for example through a loft or garage conversion, should be upgraded to the column (b) value. Paragraph 4.13 allows a lesser upgrade only where the improved value is not technically or functionally feasible or would not achieve a simple payback of 15 years or less. Paragraph 4.8 requires a replacement element to be no worse than the one it replaces as well as meeting Table 4.2. Paragraph 4.10 gives the heritage exception: where character must be maintained, a centre pane U-value of no more than 1.2 or low-emissivity secondary glazing. Note 9 records that the timber window concession of 1.6 or Band C ended on 14 June 2023. The 2021 edition came into force on 15 June 2022; a 2026 edition exists at https://assets.publishing.service.gov.uk/media/69c122a6cfa346b9d4704a55/ADL1_2026.pdf.
  5. 5costsupplier figurePremier SIPs.RN-EFWZO6A price, true at 2026-09. A UK SIP maker's product listing pricing a 172 mm polyurethane-core SIP with OSB3 facings at £150.00 inc. VAT for a 2440 × 1220 mm panel, about £50 per m² supply only.
  6. 6technicalsupplier figureKingspan Insulation, guidance.RN-VMYWEUKingspan's product page for its TEK structural insulated panel system states the air leakage it can achieve and that the system is BBA certified.
  7. 7technicalvery strongMinistry of Housing, Communities and Local Government.RN-J0UZDBApproved Document B Volume 1, fire safety in dwellings, 2019 edition with the 2020, 2022 and 2025 amendments and the forthcoming 2026 and 2029 changes collated in. Covers means of warning and escape, internal fire spread through linings and structure, external fire spread and access for the fire service. This is the document behind escape window sizes, protected stairways, the 4.5 metre rule and the fire doors a loft conversion needs.
  8. 8technicalstrongUnited Kingdom Accreditation Service.RN-BNGAIDThe live UKAS register of accredited bodies currently under sanction. It records the British Board of Agrement under imposed suspension from 26 February 2026 across all four of its accreditations: ISO/IEC 17065 product certification and ISO/IEC 17021 management systems under reference 0113, ISO/IEC 17020 inspection under 4345, and ISO/IEC 17025 testing under 0357. This is the page to check before repeating any advice that treats a BBA certificate as accredited third party assurance.
  1. Stakeholder guide to structural insulated panels (SIPs), Structural Timber Association, accessed 30 September 2026. structuraltimber.co.uk

  2. SIP Panels, Future SIPs, accessed 30 September 2026. futuresips.co.uk

  3. Kingspan TEK Building System Specification Manual, Kingspan Insulation, accessed 30 September 2026. store.filerobot.com

  4. Approved Document L, Conservation of fuel and power, Volume 1: Dwellings, 2021 edition incorporating 2023 amendments, Ministry of Housing, Communities and Local Government, accessed 14 September 2026. assets.publishing.service.gov.uk

  5. 172mm SIP Panel, Premier SIPs, accessed 30 September 2026. Priced at 2026-09 and left there. premiersips.co.uk

  6. TEK Building System, Kingspan Insulation, accessed 30 September 2026. insulation.kingspan.com

  7. Approved Document B (fire safety) volume 1: Dwellings, 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments, Ministry of Housing, Communities and Local Government, accessed 14 September 2026. assets.publishing.service.gov.uk

  8. Organisations under sanction, United Kingdom Accreditation Service, accessed 7 September 2026. ukas.com