House cladding serves two purposes: it protects the external envelope from water ingress and wind, and it dramatically changes the appearance of a property. In 2026, fully installed cladding costs range from £30/m² for a basic monocouche render to £150/m² or more for engineered composite or hardwood timber boards, including materials, fixings, battens, breather membrane, and labour.

The UK’s temperate, wet climate means durability and vapour management are critical — the wrong cladding system or a poor installation will cause interstitial condensation, mould, and structural decay within a few years.

Types of House Cladding

1. Timber Cladding

The most traditional choice for UK homes. Commonly used profiles:

  • Feather-edge / weatherboard — overlapping tapered boards, typically 100–150 mm face width
  • Tongue and groove — boards sit flush, horizontal or vertical
  • Shiplap — rebated boards with a shadow gap

Species used in the UK include Siberian larch, Douglas fir, Western red cedar, and Accoya (modified timber). Untreated timber must be maintained every 3–5 years; pre-treated or modified timber extends maintenance intervals.

2. Composite / Fibre Cement Cladding

Fibre cement boards (e.g., boards 8–12 mm thick, pre-primed) offer the look of timber with significantly lower maintenance. They are not combustible (Class A2-s1, d0 in most formulations), which has made them popular following post-Grenfell cladding regulations. Composite WPC (wood-plastic composite) boards are another option.

3. Render Systems (EWI or Monocouche)

External Wall Insulation (EWI) with a silicone or monocouche render finish is not strictly “cladding” but achieves a similar visual outcome while adding insulation. Very popular on solid-wall properties.

4. Brick Slips

Thin brick veneers (20–25 mm) bonded or mechanically fixed to a substrate. Gives a traditional brick appearance on a non-brick building or on sections of a renovation. Particularly popular for ground-floor feature walls on extensions.

5. Metal / Rainscreen Cladding

Aluminium, zinc, or steel panels fixed on a ventilated rainscreen system. Common on contemporary builds and commercial properties, increasingly used on high-end domestic projects.

House Cladding Cost Comparison Table

MaterialSupply Cost (per m²)Installed Cost (per m²)LifespanMaintenance
Monocouche render£8–£15£30–£5020–30 yrsLow (clean/paint cycle ~10 yrs)
EWI render system£40–£80£80–£12025–40 yrsLow
Untreated softwood weatherboard£10–£20£50–£8020+ yrs (if maintained)Stain every 3–5 yrs
Pre-treated larch£20–£40£60–£9030+ yrsStain every 5–7 yrs
Accoya modified timber£35–£60£80–£12050+ yrsLow
Fibre cement board£25–£50£60–£10030–40 yrsRepaint every 8–12 yrs
Brick slips£40–£80£90–£15050+ yrsVery low
Composite WPC£30–£55£70–£11025–30 yrsVery low
Aluminium rainscreen£50–£120£100–£20040–60 yrsVery low

Installed costs include battens (for ventilated systems), breather membrane, fixings, and labour.

What’s Included in a Cladding Installation?

A professional installation should include:

  1. Removal of existing render or cladding (if applicable) — adds £8–£15/m²
  2. Substrate check and repair — structural defects in the substrate must be fixed first
  3. Breather membrane — vapour-permeable membrane over the sheathing (required for all ventilated cladding systems under BS 5534 or BS 8000-6)
  4. Counter battens and horizontal battens — creating a ventilated cavity (minimum 25 mm) per NHBC Chapter 6.9
  5. Cladding boards with appropriate fixings — stainless steel or A2-grade fixings for corrosion resistance
  6. Flashings and trims — particularly around windows, doors, and at eaves and soffits
  7. Mastic / sealant — at all penetrations and junctions

Planning and Building Regulations

Planning permission — re-cladding an existing property is generally permitted development in England, unless:

  • The property is listed
  • It is in a conservation area and the cladding changes the material character
  • The new cladding is a material that would be restricted in the area (e.g., some Article 4 directions restrict cladding)

Always check with the LPA if in doubt.

Building Regulations Part B (Fire safety) — following the Building Safety Act 2022 and associated regulations, buildings over 11 m (and especially over 18 m) face strict controls on cladding materials. For domestic extensions and single-family houses under 11 m, the rules are less stringent but combustibility should still be considered — avoid expanded polystyrene (EPS) foam in any ventilated void adjacent to combustible structure.

Building Regulations Part L (Thermal performance) — if you are cladding a solid wall and the work represents an upgrade opportunity, Part L requires you to install insulation to achieve a U-value of at most 0.30 W/m²K for the wall. This is a consequential improvement requirement triggered by the refurbishment work.

Tips for Getting the Right Result

  • Specify properly — cheap fixings corrode and stain timber within 5 years; always specify A2 or A4 stainless.
  • Detail the junctions carefully — most cladding failures start at windowsills, corners, and base of cladding where water ponds.
  • Ventilated vs. direct fix — timber and many composites must be installed on a ventilated system; direct-bonded cladding traps moisture.
  • Get three quotes from specialist cladding contractors — not general builders who occasionally do cladding. Ask for a system warranty backed by the manufacturer.